BENCH TOP CONTROL PANELS

Standard Features Included

1. NEMA Type 4 or NEMA Type 12 – Both Painted Steel Wall Mount Enclosures
2. Main Disconnect w/Breaker
3. Proportional Integral Derivative (PID) Digital Control w/Process Alarm
4. Power Cycling Devices Solid State Relay (SSR)
5. Control Power On/Off Selector Switch
6. Power Light On (Green)
7. Alarm Light (Red)
8. Reset Push Button Mometary (Black)
9. Alarm Dry Contact NO/NC (For Customer Supplied OK To Run Signal)
10. Sensor RTD M12 Patch Cord, 3 Meters, Straight Male/Right Angle Female
11. M12 Receptacles
12. Heater Patch Cord, 3 Meters, w/Male & Female Bulkhead Connectors
13. Heater Mating Bulkhead Type Receptacle
14. Power Supply Cord 12-14 AWG 15 Amp, 3 Meters      
15. All Necessary Pre-Wiring, Sub-Fusing, and Terminal Blocks    
16. Funtionality Tested          
17. Schematic 2-D CAD Design          

**Special Options: Consult with Southeast Thermal Systems**

Portable Console Controller (Portable Control Panel)

Bench Top

Calculators

Power Flow Rate Temp Calculator

Calculate the electrical power, flow rate or temperature requirement.
airflow in standard cubic feet per minute
temperature rise in degrees F from the inlet to the exhaust
Watts = SCFM x ΔT/2.5

Temperature Conversion Calculator

Calculate the electrical power, flow rate or temperature requirement.
°F = ((( °C * 9) / 5 ) + 32)
°C = ((( °F - 32) * 5 ) / 9)

Three-Phase Unit Calculator

Fill in two values to find the 3rd.
W = LC * (V * √2)
V = (W / LC) / √2
LC = W / (V * √2)

Single Phase Unit Calculator

Fill in two values to find the 3rd.
W = LC * V
V = LC * W
LC = W / V

Ohms Law Calculator

Fill in two values to find the other two.

O = V / A

O = V² / W

O = W / A²

V = A * O = A * (V/A)

V = √(W * O)

V = W / A

A = V / O

A = W/ V

A = √(W / O)

W = A * V

W = V² / O

W = A² * O

Heat Transfer Through Convection Calculator

ρ = density (lb/ft3)

V = volume flow rate (ft3/hour)

Cp = specific heat (Btu/lb°F)

Ta-Tb = temperature differential (°F)

Q = ρ x V x Cp x (Ta-Tb)


Fill in four values

ρ = density (lb/ft3)
V = volume flow rate (ft3/hour)
Cp = specific heat (Btu/lb°F)
Ta-Tb = TD (°F)
Q = ρ x V x Cp x (Ta-Tb)

ACFM to SCFM

ACFM = airflow in actual cubic feet per minute

P = gage pressure (psi)

T = gas temperature °R = 460 + °F

SCFM = airflow in standard cubic feet per minute


Find Standard Cubic Feet per Minute based on data from your Actual Cubic Feet per Minute Rotameter

airflow in actual cubic feet per minute
gage pressure (psi)
gas temperature °R = 460 + °F
airflow in standard cubic feet per minute

Standard Flow Rate (SCFM) Calculator

Calculate the SCFM.
Actual cubic feet per minute
Actual pounds per square inch at Gauge
Actual temperature in °F. °R = 460 + °F
CFM * (PSI actual / 14.7psi)*(528°R / T actual)

Pressure Conversion

Fill in one value to calculate the other.
PSI = Bar * 14.504
Bar = PSI / 14.504

Mass Flow to volume Metric Flow

Fill in one value to calculate the other two
kg/h = Kilogram Per Hour (lb/min multiply by 27.216)
Lbs/min = Pounds per minute (kg/h divide by 27.216)
SCFM = Standard cubic feet per minute

Power converter for different voltage

Power converter for different voltage
Original voltage in volts (V)
Original power in watts (W)
new voltage in volts (V)
New Power = (New Voltage × Original Power) / Original Voltage

Power Flow Rate Temp Calculator

Calculate the electrical power, flow rate or temperature requirement.
airflow in standard cubic feet per minute
temperature rise in degrees F from the inlet to the exhaust
Watts = SCFM x ΔT/2.5

Temperature Conversion Calculator

Calculate the electrical power, flow rate or temperature requirement.
°C = ((( °F - 32) * 5 ) / 9)
°F = ((( °C * 9) / 5 ) + 32)

Three-Phase Unit Calculator

Fill in two values to find the 3rd.
W = LC * (V * √2)
V = (W / LC) / √2
LC = W / (V * √2)

Single Phase Unit Calculator

Fill in two values to find the 3rd.
W = LC * V
V = LC * W
LC = W / V

Ohms Law Calculator

Fill in two values to find the other two.

O = V / A

O = V² / W

O = W / A²

V = A * O = A * (V/A)

V = √(W * O)

V = W / A

A = V / O

A = W/ V

A = √(W / O)

W = A * V

W = V² / O

W = A² * O

Heat Transfer Through Convection Calculator

ρ = density (lb/ft3)

V = volume flow rate (ft3/hour)

Cp = specific heat (Btu/lb°F)

Ta-Tb = temperature differential (°F)

Q = ρ x V x Cp x (Ta-Tb)


Fill in four values

ρ = density (lb/ft3)
V = volume flow rate (ft3/hour)
Cp = specific heat (Btu/lb°F)
Ta-Tb = TD (°F)
Q = ρ x V x Cp x (Ta-Tb)

ACFM to SCFM

ACFM = airflow in actual cubic feet per minute

P = gage pressure (psi)

T = gas temperature °R = 460 + °F

SCFM = airflow in standard cubic feet per minute


Find Standard Cubic Feet per Minute based on data from your Actual Cubic Feet per Minute Rotameter

airflow in actual cubic feet per minute
gage pressure (psi)
gas temperature °R = 460 + °F
airflow in standard cubic feet per minute

Standard Flow Rate (SCFM) Calculator

Calculate the SCFM.
Actual cubic feet per minute
Actual pounds per square inch at Gauge
Actual temperature in °F. °R = 460 + °F
CFM * (PSI actual / 14.7psi)*(528°R / T actual)

Pressure Conversion

Fill in one value to calculate the other.
PSI = Bar * 14.504
Bar = PSI / 14.504

Mass Flow to volume Metric Flow

Fill in one value to calculate the other two
Kg/h = Kilogram Per Hour (lb/min multiply by 27.216)
Lbs/min = Pounds per minute (kg/h divide by 27.216)
SCFM = Standard cubic feet per minute

Power converter for different voltage

Power converter for different voltage
Original voltage in volts (V)
Original power in watts (W)
new voltage in volts (V)
New Power = (New Voltage × Original Power) / Original Voltage