704-399-4248 sales@sethermal.com

3″, 5″ & 6″ 150 # FLANGED IMMERSION HEATERS STANDARD SIZES

<-FLANGED IMMERSION HEATERS

8″ & 10″ – 150# FLANGED IMMERSION HEATERS STANDARD SIZES ->

3″ – 150# Standard Flange Immersion Heaters

150lb Flanged Immersion heater

 

48 Watts per sq. inch – Water & Mild Solutions

Immersed Length “B”

Volts 3=Ph.

KW

No. Circ.

Wt. (lbs.)

C

D. Max

E

F

G

H

18″

240

6

1

16

3 ½

2 ⅞

4

7 ½

6

4

480

19 ⅞”

240

7.5

1

16

3 ½

2 ⅞

4

7 ½

6

4

480 1

25 ¼”

240

9

1

17

3 ½

2 ⅞

4

7 ½ 6

4

480 1

33″

240

12

1

18

3 ½

2 ⅞

4

7 ½ 6

4

480 1

40 ¾”

240

15

1

20

3 ½

2 ⅞

4

7 ½ 6

4

480 1

48″

240

18

1

21

3 ½

2 ⅞ 4 7 ½ 6 4
480 1

52″

240

20

1

21

3 ½

2 ⅞ 4 7 ½ 6 4
480 1

61 ½”

240

25

1

22

3 ½

2 ⅞ 4 7 ½ 6 4
480 1

78″

240

30

1

23

3 ½

2 ⅞ 4 7 ½ 6 4
480 1
23 Watts per sq. inch – Light wt. oils, caustics, air, & gases

Immersed

Volts

KW

No.

Wt.

C

D. Max

E

F

G

H

Length “B” 3-Ph. Circ. (lbs.)

18″

240

3

1

16

3 ½

2 ⅞

4

7 ½

6

4

480 1

25¼”

240

4.5

1

17

3 ½

2 ⅞

4

7 ½

6

4

480 1

33″

240

6

1

18

3 ½

2 ⅞

4

7 ½ 6

4

480 1

40 ¾”

240

7.5

1

20

3 ½

2 ⅞

4

7 ½ 6

4

480 1

48″

240

9

1

21

3 ½

2 ⅞

4

7 ½ 6

4

480 1

52″

240

10

1

21

3 ½

2 ⅞ 4 7 ½ 6 4
480 1

65″

240

12.5

1

22

3 ½

2 ⅞ 4 7 ½ 6 4
480 1

78″

240

15

1

23

3 ½

2 ⅞ 4 7 ½ 6 4
480 1

 

13 Watts per sq. inch – Med. wt. oils, No. 4 & 5 fuel oil, corrosives, air & gases

Immersed

Volts

KW

No.

Wt.

C

D. Max

E

F

G

H

Length “B”

18″

240

1.5

1

16

3 ½

2 ⅞

4

7 ½

6

4

480 1

25¼”

240

2.25

1

17

3 ½

2 ⅞

4

7 ½

6

4

480 1

33″

240

3

1

18

3 ½

2 ⅞

4

7 ½ 6

4

480 1

40 ¾”

240

3.75

1

20

3 ½

2 ⅞

4

7 ½ 6

4

480 1

48″

240

4.5

1

21

3 ½

2 ⅞

4

7 ½ 6

4

480 1

52″

240

5

1

21

3 ½

2 ⅞ 4 7 ½ 6 4
480 1

61 ½”

240

6.25

1

22

3 ½

2 ⅞ 4 7 ½ 6 4
480 1

78″

240

7.5

1

23

3 ½

2 ⅞ 4 7 ½ 6 4
480 1

 

8 Watts per sq. inch – Heavy oils, #6 & Bunker C fuel oils, air & gases
Immersed Volts KW No. Wt. C D. Max E F G H
Length “B”
25¼” 240 1.5 1 17 3 ½ 2 ⅞ 4 7 ½ 6 4
480 1
33″ 240 2 1 18 3 ½ 2 ⅞ 4 7 ½ 6 4
480 1
40 ¾” 240 2.5 1 20 3 ½ 2 ⅞ 4 7 ½ 6 4
480 1
48″ 240 3 1 21 3 ½ 2 ⅞ 4 7 ½ 6 4
480 1
52″ 240 3.3 1 21 3 ½ 2 ⅞ 4 7 ½ 6 4
480 1
65″ 240 4.2 1 22 3 ½ 2 ⅞ 4 7 ½ 6 4
480 1
78″ 240 5 1 23 3 ½ 2 ⅞ 4 7 ½ 6 4
480 1

5″ – 150# Standard Flange Immersion Heaters

150lb Flanged Immersion heater
48 Watts per sq. inch – Water & Mild Solutions

Immersed Length “B”

Volts 3 Ph.

KW

No. Circ.

Wt. (lbs.)

C

D. Max

E

F

G

H

J

K

18″

240

12

1

30

5

4 ⅝

6

10

8 ½

8

516

480 1

19 ⅞”

240

15

1

31

5

4 ⅝

6

10

8 ½

8

516

480 1

25 ¼”

240

18

1

33

5 4 ⅝ 6 10 8 ½ 8 516
480 1

33″

240

24

2

37

5 4 ⅝ 6 10 8 ½ 8 516
480 1

40 ¾”

240

30

2

40

5 4 ⅝ 6 10 8 ½ 8 516
480 1

48″

240

36

2

45

5 4 ⅝ 6 10 8 ½ 8 516
480 1

52″

240

40

2

47

5 4 ⅝ 6 10 8 ½ 8 516
480 1

61 ½”

240

50

2

50

5 4 ⅝ 6 10 8 ½ 8 516
480 2

78″

240

60

2

55

5 4 ⅝ 6 10 8 ½ 8 516
480 2

23 Watts per sq. inch – Light wt. oils, caustics, air, & gases

Immersed Length “B”

Volts 3 Ph.

KW

No. Circ.

Wt. (lbs.)

C

D. Max

E

F

G

H

J

K

18″

240

6

1

30

5

4 ⅝

6

10

8 ½

8

516

480 1

25¼”

240

9

1

33

5

4 ⅝

6

10

8 ½

8

516

480 1

33″

240

12

1

37

5 4 ⅝ 6 10 8 ½ 8 516
480 1

40 ¾”

240

15

1

40

5 4 ⅝ 6 10 8 ½ 8 516
480 1

48″

240

18

1

45

5 4 ⅝ 6 10 8 ½ 8 516
480 1

52″

240

20

1

47

5 4 ⅝ 6 10 8 ½ 8 516
480 1

65″

240

25

1

50

5 4 ⅝ 6 10 8 ½ 8 516
480 1

78″

240

30

1

55

5 4 ⅝ 6 10 8 ½ 8 516
480 1

 

13 Watts per sq. inch – Med. wt. oils, No. 4 & 5 fuel oil, corrosives, air & gases

Immersed Length “B”

Volts 3 Ph.

KW

No. Circ.

Wt. (lbs.)

C

D. Max

E

F

G

H

J

K

18″

240

3

1

30

5

4 ⅝

6

10

8 ½

8

516

480 1

25¼”

240

4.5

1

33

5

4 ⅝

6

10

8 ½

8

516

480 1

33″

240

6

1

37

5 4 ⅝ 6 10 8 ½ 8 516
480 1

40 ¾”

240

7.5

1

40

5 4 ⅝ 6 10 8 ½ 8 516
480 1

48″

240

9

1

45

5 4 ⅝ 6 10 8 ½ 8 516
480 1

52″

240

10

1

47

5 4 ⅝ 6 10 8 ½ 8 516
480 1

61 ½”

240

12.5

1

50

5 4 ⅝ 6 10 8 ½ 8 516
480 1

78″

240

15

1

55

5 4 ⅝ 6 10 8 ½ 8 516
480 1

8 Watts per sq. inch – Heavy oils, #6 & Bunker C fuel oils, air & gases

Immersed Length “B”

Volts 3 Ph.

KW

No. Circ.

Wt. (lbs.)

C

D. Max

E

F

G

H

J

K

25¼”

240

3

1

33

5

4 ⅝

6

10

8 ½

8

516

480 1

33″

240

4

1

37

5

4 ⅝

6

10

8 ½

8

516

480 1

40 ¾”

240

5

1

40

5 4 ⅝ 6 10 8 ½ 8 516
480 1

48″

240

6

1

45

5 4 ⅝ 6 10 8 ½ 8 516
480 1

52″

240

7

1

47

5 4 ⅝ 6 10 8 ½ 8 516
480 1

65″

240

8.4

1

50

5 4 ⅝ 6 10 8 ½ 8 516
480 1

78″

240

10

1

55 5 4 ⅝ 6 10 8 ½ 8 516
480 1

6″ – 150# Standard Flange Immersion Heaters

150lb Flanged Immersion heater

 

48 Watts per sq. inch – Water & Mild Solutions

Immersed Length “B”

Volts 3 Ph.

KW

No. Circ.

Wt. (lbs.)

C

D. Max

E

F

G

H

J

K

18″

240

24

2

53

5

5 ½

6

11

9 ½

8

516

480 1

19 ⅞”

240

30

2

55

5

5 ½

6

11

9 ½

8

516

480 1

25 ¼”

240

36

2

57

5 5 ½ 6 11 9 ½ 8 516
480 1

33″

240

48

4

60

5 5 ½ 6 11 9 ½ 8 516
480 2

40 ¾”

240

60

4

65

5 5 ½ 6 11 9 ½ 8 516
480 2

48″

240

72

4

68

5 5 ½ 6 11 9 ½ 8 516
480 2

52″

240

80

4

70

5 5 ½ 6 11 9 ½ 8 516
480 2

61 ½”

240

100

4

75

5 5 ½ 6 11 9 ½ 8 516
480 2

78″

240

120

4

85

5 5 ½ 6 11 9 ½ 8 516
480 2

23 Watts per sq. inch – Light wt. oils, caustics, air, & gases

Immersed Length “B”

Volts 3 Ph.

KW

No. Circ.

Wt. (lbs.)

C

D. Max

E

F

G

H

J

K

18″

240

12

1

53

5

5 ½

6

11

9 ½

8

516

  480   1  

25¼”

240

18

1

57

5 5 ½ 6 11 9 ½ 8 516
  480   1  

33″

240

24

2

60

5 5 ½ 6 11 9 ½ 8 516
  480   1  

40 ¾”

240

30

2

65

5 5 ½ 6 11 9 ½ 8 516
  480   1  

48″

240

36

2

68

5 5 ½ 6 11 9 ½ 8 516
  480   1  

52″

240

40

2

70

5 5 ½ 6 11 9 ½ 8 516
  480   1  

65″

240

50

4

75

5 5 ½ 6 11 9 ½ 8 516
  480   2  

78″

240

60

4

85

5 5 ½ 6 11 9 ½ 8 516
  480   2  

 

13 Watts per sq. inch – Med. wt. oils, No. 4 & 5 fuel oil, corrosives, air & gases

Immersed Length “B”

Volts 3 Ph.

KW

No. Circ.

Wt. (lbs.)

C

D. Max

E

F

G

H

J

K

18″

240

6

1

53

5

5 ½

6

11

9 ½

8

516

  480   1  

25¼”

240

9

1

57

5 5 ½ 6 11 9 ½ 8 516
  480   1  

33″

240

12

1

60

5 5 ½ 6 11 9 ½ 8 516
  480   1  

40 ¾”

240

15

1

65

5 5 ½ 6 11 9 ½ 8 516
  480   1  

48″

240

18

1

68

5 5 ½ 6 11 9 ½ 8 516
  480   1  

52″

240

20

2

70

5 5 ½ 6 11 9 ½ 8 516
  480   1  

61 ½”

240

25

2

75

5 5 ½ 6 11 9 ½ 8 516
  480   1  

78″

240

30

2

85

5 5 ½ 6 11 9 ½ 8 516
  480   1  

 

8 Watts per sq. inch – Heavy oils, #6 & Bunker C fuel oils, air & gases

Immersed Length “B”

Volts 3 Ph.

KW

No. Circ.

Wt. (lbs.)

C

D. Max

E

F

G

H

J

K

25¼”

240

6

1

57

5

5 ½

6

11

9 ½

8

516

  480   1  

33″

240

8

1

60

5 5 ½ 6 11 9 ½ 8 516
  480   1  

40 ¾”

240

10

1

65

5 5 ½ 6 11 9 ½ 8 516
  480   1  

48″

240

12

1

68

5 5 ½ 6 11 9 ½ 8 516
  480   1  

52″

240

13.3

1

70

5 5 ½ 6 11 9 ½ 8 516
  480   1  

65″

240

16.7

1

78

5 5 ½ 6 11 9 ½ 8 516
  480   1  

78″

240

20

1

85

5 5 ½ 6 11 9 ½ 8 516
  480   1