704-399-4248 sales@sethermal.com
SELF CONTAINED (VACUUM) HOPPER LOADERS SPECS.
Model #  Conveying Capacity (lbs) Hopper Caacity (lbs)
SAL-1U 66 1
SAL-3U 440 3
SAL6U 660 7
SAL-12U 900

15

GLASS TUBE HOPPER WITH PHOTO SENSOR
Model # Conveying Capacity (lbs/hr) Hopper  Capacity (lbs)
SAL-3UE 440 3
DESCRIPTION

The Shini USA SHR-U and SHR-U-E Receivers are constructed of high quality stainless steel and feature a vacuum sequencing valve. Stainless steel bodies and also feature.

  • Vacuum sequencing valve
  • Six pin plug for connection to SAL-UG Control
  • Dust collection bin for ease of cleaning
VENTURI (COMPRESSED AIR) LOADERS SPECS.
Model # Conveying Capacity (lbs/hr) Level Switch
VL-50 88 Glass Tube Hopper with Photo Sensor
VL-120 176 Glass Tube Hopper with Photo Sensor
DESCRIPTION

Utilizing a vacuum, the compressed air hopper loader draws material from drums, bins or gaylords. From here, the material is conveyed via compressed air to the stainless steel receiving hopper. Manufactured using stainless steel, our compressed air hopper loaders are lightweight and compact, making them an ideal addition to your operations. Each Compressed Air Venturi Loader comes equipped with a number of features that aid in optimal efficiency. Our Compressed Air Venturi Loaders feature:

Stainless steel hopper and base
Material pick-up wand
Low maintenance filter assembly
Wide diameter hopper to keep material flowing without bridging
Material demand sensor
Compact size
Lightweight body
Filtered exhaust
Level sensor in glass-tube signals material status
Compressed air filter and regulator
Quick release clamps on base for easy cleaning
Adjustable direction of hopper and base
1 1/4″ x 12′ flex PVC material hose

PROPORTIONAL VALVES SPECS.
Model # Maximum Material Flow Cap. (lbs/hr) Pipe Size
SPV-38U 770 1.5
SPV-50U 1200 2
SPV-38UC 770 1.5
SPV-50UC 1200 2
DESCRIPTION

Proportional Valves from Shini USA are designed to provide consistent control of pressure and flow. Highly efficient in mixing the virgin and regrind material, the Shini USA, Division of Budzar Industries Proportional Valve is easily installed, mounts directly onto the hopper loader or the pipeline.

Calculators

Power Flow Rate Temp Calculator

Calculate the electrical power, flow rate or temperature requirement.
airflow in standard cubic feet per minute
temperature rise in degrees F from the inlet to the exhaust
Watts = SCFM x ΔT/2.5

Temperature Conversion Calculator

Calculate the electrical power, flow rate or temperature requirement.
°F = ((( °C * 9) / 5 ) + 32)
°C = ((( °F - 32) * 5 ) / 9)

Three-Phase Unit Calculator

Fill in two values to find the 3rd.
W = LC * (V * √2)
V = (W / LC) / √2
LC = W / (V * √2)

Single Phase Unit Calculator

Fill in two values to find the 3rd.
W = LC * V
V = LC * W
LC = W / V

Ohms Law Calculator

Fill in two values to find the other two.

O = V / A

O = V² / W

O = W / A²

V = A * O = A * (V/A)

V = √(W * O)

V = W / A

A = V / O

A = W/ V

A = √(W / O)

W = A * V

W = V² / O

W = A² * O

Heat Transfer Through Convection Calculator

ρ = density (lb/ft3)

V = volume flow rate (ft3/hour)

Cp = specific heat (Btu/lb°F)

Ta-Tb = temperature differential (°F)

Q = ρ x V x Cp x (Ta-Tb)


Fill in four values

ρ = density (lb/ft3)
V = volume flow rate (ft3/hour)
Cp = specific heat (Btu/lb°F)
Ta-Tb = TD (°F)
Q = ρ x V x Cp x (Ta-Tb)

ACFM to SCFM

ACFM = airflow in actual cubic feet per minute

P = gage pressure (psi)

T = gas temperature °R = 460 + °F

SCFM = airflow in standard cubic feet per minute


Find Standard Cubic Feet per Minute based on data from your Actual Cubic Feet per Minute Rotameter

airflow in actual cubic feet per minute
gage pressure (psi)
gas temperature °R = 460 + °F
airflow in standard cubic feet per minute

Standard Flow Rate (SCFM) Calculator

Calculate the SCFM.
Actual cubic feet per minute
Actual pounds per square inch at Gauge
Actual temperature in °F. °R = 460 + °F
CFM * (PSI actual / 14.7psi)*(528°R / T actual)

Pressure Conversion

Fill in one value to calculate the other.
PSI = Bar * 14.504
Bar = PSI / 14.504

Mass Flow to volume Metric Flow

Fill in one value to calculate the other two
kg/h = Kilogram Per Hour (lb/min multiply by 27.216)
Lbs/min = Pounds per minute (kg/h divide by 27.216)
SCFM = Standard cubic feet per minute

Power Flow Rate Temp Calculator

Calculate the electrical power, flow rate or temperature requirement.
airflow in standard cubic feet per minute
temperature rise in degrees F from the inlet to the exhaust
Watts = SCFM x ΔT/2.5

Temperature Conversion Calculator

Calculate the electrical power, flow rate or temperature requirement.
°C = ((( °F - 32) * 5 ) / 9)
°F = ((( °C * 9) / 5 ) + 32)

Three-Phase Unit Calculator

Fill in two values to find the 3rd.
W = LC * (V * √2)
V = (W / LC) / √2
LC = W / (V * √2)

Single Phase Unit Calculator

Fill in two values to find the 3rd.
W = LC * V
V = LC * W
LC = W / V

Ohms Law Calculator

Fill in two values to find the other two.

O = V / A

O = V² / W

O = W / A²

V = A * O = A * (V/A)

V = √(W * O)

V = W / A

A = V / O

A = W/ V

A = √(W / O)

W = A * V

W = V² / O

W = A² * O

Heat Transfer Through Convection Calculator

ρ = density (lb/ft3)

V = volume flow rate (ft3/hour)

Cp = specific heat (Btu/lb°F)

Ta-Tb = temperature differential (°F)

Q = ρ x V x Cp x (Ta-Tb)


Fill in four values

ρ = density (lb/ft3)
V = volume flow rate (ft3/hour)
Cp = specific heat (Btu/lb°F)
Ta-Tb = TD (°F)
Q = ρ x V x Cp x (Ta-Tb)

ACFM to SCFM

ACFM = airflow in actual cubic feet per minute

P = gage pressure (psi)

T = gas temperature °R = 460 + °F

SCFM = airflow in standard cubic feet per minute


Find Standard Cubic Feet per Minute based on data from your Actual Cubic Feet per Minute Rotameter

airflow in actual cubic feet per minute
gage pressure (psi)
gas temperature °R = 460 + °F
airflow in standard cubic feet per minute

Standard Flow Rate (SCFM) Calculator

Calculate the SCFM.
Actual cubic feet per minute
Actual pounds per square inch at Gauge
Actual temperature in °F. °R = 460 + °F
CFM * (PSI actual / 14.7psi)*(528°R / T actual)

Pressure Conversion

Fill in one value to calculate the other.
PSI = Bar * 14.504
Bar = PSI / 14.504

Mass Flow to volume Metric Flow

Fill in one value to calculate the other two
Kg/h = Kilogram Per Hour (lb/min multiply by 27.216)
Lbs/min = Pounds per minute (kg/h divide by 27.216)
SCFM = Standard cubic feet per minute